School and classroom acoustics ensures students hear the teacher clearly, neighbouring classrooms do not bleed in, and learning performance stays high. Children are far more sensitive to acoustic comfort than adults; international standards recommend RT60 0.4-0.5 s and STI 0.65+ for classrooms.
School acoustics — special importance for children
A child's hearing system is not yet fully developed; in a reverberant classroom they may misperceive 30-40% of what the teacher says. The result is reduced learning performance, more fatigue and shorter attention. International education-acoustic standards are therefore strict.
Typical problems
- Teacher speech distorted in a reverberant classroom
- Lesson noise from the next classroom
- Sound bleeding from corridors into the classroom
- HVAC fan noise disturbing students
- Gym / canteen noise spilling into lessons
Solution components
In-classroom acoustics (Absorb)
- Acoustic ceiling (NRC ≥ 0.90)
- Wall absorber panels (rear or side wall)
- Acoustic carpet (floor)
- RT60 target: 0.4-0.5 s
Inter-classroom sound insulation (Block)
- Partition wall Rw 45+ dB
- Acoustic door Rw 30+ dB
- Acoustic glazing (where there is glass)
School-wide acoustics
- Sports hall isolation
- Canteen / lobby acoustic ceiling
- Music / drama rooms (specialist acoustics)
- Conference / event hall
STI and learning performance
When STI (Speech Transmission Index) is above 0.65, children follow the lesson comfortably. In our field measurements, untreated classrooms typically score STI 0.40-0.55; after acoustic treatment they reach 0.70+.
Target performance
- RT60: 0.4-0.5 seconds
- STI: 0.65+
- Partition Rw: 45+ dB
- NC: 30-35
- Acoustic door Rw: 30+ dB
Budget prioritisation
Tight budgets in school refurbs often mean not every space can be treated at once. Our practice prioritises: in-classroom acoustics first, then inter-classroom partitions, gym/event spaces last.
Time and cost
A typical classroom 1-2 days (summer holiday is ideal). A whole-school refurb 4-8 weeks, scheduled around the summer.
Certification
Educational spaces require EN 13501-1 A2-s1, d0 fire-class materials; antibacterial-faced acoustic ceilings are preferred.
Features
On-site acoustic measurement and noise source analysis
Detailed engineering with professional simulation software
Certified material selection (BS476 Class 0, UNI 9175)
Meticulous installation and execution with our experienced team
Final measurement and performance warranty report
Process
Survey & Measurement
On-site survey and acoustic measurement.
Simulation & Design
Simulation with acoustic software, detailed quote.
Installation
Turnkey installation with certified materials.
Verification & Report
Final measurement, performance report, warranty.
Technical Specifications
| Application Standard | BS476 Class 0, UNI 9175 M1, Firex |
|---|---|
| Typical Noise Reduction | 25-45 dB (project-dependent) |
| Installation Time | Confirmed after survey (1-15 days) |
| Warranty | Measured result + 2-year workmanship warranty |