Mechanical and industrial sound insulation isolates the high-level (95-110 dBA) noise generated by generators, chillers, compressors, fans and factory equipment from the surroundings and other building spaces. Combining double-leaf enclosures, splitter silencers, vibration-damping bases and certified acoustic doors, we target 45-65 dB reduction. Compliance with the Environmental Noise Regulation is guaranteed.
What is mechanical and industrial sound insulation?
Industrial sound insulation is the engineering discipline of controlling the high-decibel continuous noise produced by production and mechanical equipment. Unlike residential insulation, it requires performance in the low-frequency band caused by motors and fans rather than the high frequencies. Vibration, temperature and air-flow conditions are integrated into the acoustic design.
Which equipment and rooms does it cover?
- Generator room sound insulation (50-1500 kVA)
- Chillers and cooling units
- Compressors and air-compressor enclosures
- Boiler and heating-plant rooms
- Fans, blowers and air-handling units
- Pump and booster rooms
- Transformer stations
- Industrial production lines (CNC, presses, foundry)
What does a typical industrial insulation system include?
Our typical industrial enclosure is multi-layered:
- Existing concrete/curtain wall + vibroacoustic hangers
- Steel framework with 80 mm high-density rock-wool infill
- Two layers of acoustic plasterboard + elastomeric membrane
- Sound-absorbing acoustic panel on the inside (echo control)
- Acoustic door (certified, Rw 38-44 dB)
- Splitter silencers at air inlets/outlets
- Vibration-damping base (springs/elastomer)
- Exhaust silencer for generators (high-temp resistant)
How is the target dB level set?
Two measurements drive the design: the source noise level and the desired final dB outside the room. Turkey's Environmental Noise Assessment Regulation defines a residential night limit of 45 dBA and day limit of 55 dBA. Targeting 45 dBA from a 110 dBA source means a net 65 dB reduction; our experience confirms this is achievable with the right design.
Field story: how a 48 dB reduction was achieved
For a 1250 kVA diesel generator at a logistics facility in Istanbul, on the existing concrete wall we applied vibroacoustic hangers + 80 mm rock wool + double plasterboard + intermediate membrane + polyester acoustic panel inside. Splitter silencers at the air openings, a reactive silencer on the exhaust, and an Rw 44 dB acoustic door were selected. Final measurements documented a net 48 dB reduction.
Which certifications are mandatory?
Because industrial spaces are critical from a fire-code perspective, all the materials we use carry:
- BS 476 Class 0 — surface flame spread
- EN 13501-1 A2-s1, d0 — fire-resistance class
- UNI 9175 Class 1IM — Italian fire-behaviour classification
- EN ISO 717-1 Rw — certified sound-transmission loss
Time, cost and ROI
Our industrial projects run 2-8 weeks. The investment is a small fraction of the building budget but eliminates environmental fine risk, supports a positive building-inspection report and extends equipment life. Each project includes pre/post measurement and a written report.
Services We Offer in This Category
For each sub-service we apply a dedicated engineering approach and certified material selection. Click on a title to explore.
Generator sound insulation
DetailsChiller & cooling unit sound insulation
DetailsCooling tower sound insulation
DetailsBoiler room sound insulation
DetailsBooster pump (hydrophore) sound insulation
DetailsCompressor sound insulation
DetailsLift / elevator and machine room sound insulation
DetailsBlower sound insulation
DetailsFactory / production facility sound insulation
DetailsMechanical room sound insulation
DetailsWhy Dedatek?
Expert Team
With our acoustic engineers and experienced application team.
Guaranteed Results by Measurement
Pre and post application dB measurement, detailed report.
Turnkey Delivery
Survey, simulation, application, inspection — the entire process at Dedatek.
Certified Materials
BS476 Class 0, UNI 9175, Firex non-flammability standards.
Process
Inspection & Measurement
On-site acoustic measurement and noise source identification.
Simulation & Design
Acoustic simulation and detailed project with professional software.
Installation
Installation with certified materials by our experienced team.
Inspection & Report
Result measurement and performance guarantee report.
Standards & Certifications
- BS476 Class 0 (non-flammable)
- UNI 9175:2008 M1
- Firex non-flammability certificate
- CE / ISO / TSE compliance