Chiller & cooling unit sound insulation

We reduce the fan/compressor noise of chillers and cooling units placed on roofs, terraces or in mechanical rooms by 25-40 dB with acoustic screens, enclosures and vibration damping.

Summary

Chiller and cooling-unit sound insulation brings fan and compressor noise of cooling devices under control with acoustic screens, enclosures and vibration-damping systems. In rooftop or terrace placements it delivers 25-40 dB reduction; it is the critical engineering solution for environmental compliance and to address neighbour complaints.

What is chiller sound insulation?

Chillers (water cooling units) are central devices for HVAC and process cooling in large buildings. High-capacity chillers produce 80-95 dBA from fan + compressor + coolant pump together. Because they are typically located on rooftops, terraces or in technical rooms, they are critical for environmental noise and vibration.

When is it needed?

  • Vibration transmission from rooftop chillers to apartments below
  • Office / residential complaints from the neighbouring building
  • Environmental Noise Regulation compliance
  • Quiet-critical premises (hotel, hospital)
  • Proactive design in a new mall or facility project

Solution components

1. Acoustic screen / enclosure

A double-leaf sandwich-panel acoustic screen or a full enclosure around the chiller delivers 20-30 dB reduction without disrupting airflow.

2. Vibration damping

An elastomer or spring vibration mount under the chiller foot reduces structural vibration transmission by 85-95%.

3. Air inlet/outlet silencer

Splitter silencers are mounted at the air inlet/outlet because cooling-air flow is mandatory.

4. Pipe and duct wrapping

Chilled-water and refrigerant pipes are wrapped with acoustic transition foam; line vibration to the building is cut.

Target performance

  • Acoustic enclosure Rw: 28-42 dB
  • Vibration reduction: 85-95%
  • Airborne reduction: 25-40 dB
  • Environmental limit: 45 dBA night, 55 dBA day

Field practice

In rooftop chiller projects we solve vibration first, because this structural transmission is independent of the room's acoustic intervention. Then airborne noise is addressed with the acoustic screen and silencer. A typical project runs 1-3 weeks.

Maintenance-friendly design

Chillers require periodic maintenance. The enclosures we design have removable acoustic doors, front cover and top panel; they do not block the maintenance-staff's access.

Certificates

All acoustic panels and silencers are EN 13501-1 A2-s1, d0 fire class and meet EN ISO 7235 silencer test standards.

Features

On-site acoustic measurement and noise source analysis

Detailed engineering with professional simulation software

Certified material selection (BS476 Class 0, UNI 9175)

Meticulous installation and execution with our experienced team

Final measurement and performance warranty report

Process

01

Survey & Measurement

On-site survey and acoustic measurement.

02

Simulation & Design

Simulation with acoustic software, detailed quote.

03

Installation

Turnkey installation with certified materials.

04

Verification & Report

Final measurement, performance report, warranty.

Technical Specifications

Application Standard BS476 Class 0, UNI 9175 M1, Firex
Typical Noise Reduction 25-45 dB (project-dependent)
Installation Time Confirmed after survey (1-15 days)
Warranty Measured result + 2-year workmanship warranty

Frequently Asked Questions

Chiller & cooling unit soundproofing — which materials do you use?
Depending on project requirements, we use acoustic foam, barrier-backed foam, lead/EPDM barrier, elastomeric rubber, rock wool and double-layer plasterboard systems. All our materials carry international fire-resistance certifications.
How much noise reduction do I get after the application?
It varies according to the existing structure, the adjacent noise level and the target use. Typical residential applications achieve 25-40 dB and industrial projects 35-55 dB. The exact value is confirmed by acoustic measurement.
Do I need to move my existing furniture?
It is enough to clear sufficient space so we can work in the application area. Our installation team takes protective measures for furniture; for small applications minimal rearrangement is sufficient.
How can I request a quote?
You can reach us by phone (+90 530 044 09 90), WhatsApp or our contact form. After a brief conversation we schedule an on-site survey.

Get an expert opinion for your project

Our team is ready for acoustic measurement, detailed engineering and turnkey delivery.

Get a Quote Call Now WhatsApp