Home sound insulation is the comprehensive solution package that addresses every acoustic problem in a residence (neighbour, upstairs, street, internal partition) with a holistic engineering approach. Multi-layer applications target Rw 50+ for every building component within the flat (walls, ceiling, floor, facade, doors, windows). After a detailed survey, a project specific to the space is prepared.
What is home sound insulation?
Home sound insulation is a holistic acoustic-engineering service that evaluates every noise source in a residence together and produces a tailored solution for each. It is not just insulating one wall — it is a 360° design approach covering the whole apartment. This is the most common approach we see in existing homes.
The most frequent noise issues in homes
- Speech / TV from a neighbour (Rw 36-42 → 50+ target)
- Footsteps from upstairs (weak ΔLw → 22+ ΔLw target)
- Street / traffic noise (weak facade Rw + Ctr)
- Insufficient internal-room separation (bedroom — living room)
- Bathroom / kitchen plumbing / pipe noise
- Lift vibration and shaft noise
How does the holistic approach work?
- Detailed survey: walking the whole flat, mapping problem points.
- Comprehensive measurement: separate Rw / ΔLw measurements for each wall/ceiling/floor.
- Prioritisation: the most disturbing source first; maximum impact for a given budget.
- Modular design: phased application plan (can start on a limited budget).
- Turnkey delivery: paint, flooring and everything restored to original.
- Final measurement: separate report for each component.
Target performance (residential comfort level)
- Party wall between flats: Rw 50-55 dB
- Upstairs ceiling: Rw 50+ + ΔLw 25+
- Facade (traffic): DnT,w + Ctr 35+ dB
- Internal-room partition: Rw 42-48 dB
- Acoustic door: Rw 32-38 dB
- Acoustic glass: Rw 38-42 dB
Phased-application approach
For budget-limited customers we recommend: instead of insulating the whole flat at once, the 1-2 most disturbing problems are solved first, then other components are added over time. The multi-layer build is composite, so additions can be retrofitted.
Building components we use
We have separate detail pages per category for each wall/ceiling/floor system.
Lead time, cost and continuing to live in the home
A typical full home insulation runs 2-4 weeks. The family can stay in the home during application; however, due to noise and dust, a 1-2 week hotel stay may be recommended. Dry systems (plasterboard, suspended ceiling) are preferred so demolition is minimal.
Features
On-site acoustic measurement and noise source analysis
Detailed engineering with professional simulation software
Certified material selection (BS476 Class 0, UNI 9175)
Meticulous installation and execution with our experienced team
Final measurement and performance warranty report
Process
Survey & Measurement
On-site survey and acoustic measurement.
Simulation & Design
Simulation with acoustic software, detailed quote.
Installation
Turnkey installation with certified materials.
Verification & Report
Final measurement, performance report, warranty.
Technical Specifications
| Application Standard | BS476 Class 0, UNI 9175 M1, Firex |
|---|---|
| Typical Noise Reduction | 25-45 dB (project-dependent) |
| Installation Time | Confirmed after survey (1-15 days) |
| Warranty | Measured result + 2-year workmanship warranty |